Aromarizer-4, Aromarizer-6 & Aromarizer-8 Instructions
Congratulations on purchasing your Airheads Aromarizer. If handled and maintained properly, your equipment will
be making money for you for many years to come. Before you start working with your new Oxygen Bar equipment
there are a few precautions that you must observe.
- Remove equipment from the packing materials carefully.
- When equipment is in operation, never let anyone smoke within a 10 foot radius of the bar.
- Always change out the water and aromas every 40 – 50 hours of use or when cloudy.
- Never reuse a used nasal cannula (nose hose).
- Never make any medical claims as to the benefits of Oxygen.
- Only use aromas approved by Airheads.
- Always clean Aromarizer components with warm water and a mild soap.
- Never get the inside electrical area of the components wet.
Setting up the Aromarizer: For "Rainbow Magic" LED Technology CLICK HERE. Carefully lift the top of the
Aromarizer off and place it aside without disconnecting any tubing. Remove all contents of the inside except for the
light fixture. Plug the power cord through the hole on the short side. Put the Aromarizer cover back on. Unwrap the
bottles and unscrew the red cap assemblies and lift out of the bottles being careful not to break the glass rods. Now
fill them with clean (or purified/distilled) water about 1½ inches from the bottom. DO NOT OVER FILL! Add 6-10
drops of the aroma to the water, (this is a personal taste issue – some like the aromas stronger than others)
keeping in mind that the aromas must match the bottle labeled with that aroma. Then slide the bottles on top of the
Aromarizer lid from rear to front. Do this very carefully by bending back the hose (with the green check valve on the
end) and sliding the bottles forward until they lock into place. Now take the red cap assembly and screw them into
each bottle hand tight, do not tighten excessively! Connect the nose hose connection tubes to the side arms of the
bottles. Connect each check valve to its corresponding red cap assembly by pushing the check valve straight down
into the top of the red cap assembly. Any excess tubing can be pushed through the holes on top of the Aromarizer
to make all the bottle assemblies look uniform. Carefully lift and move aside the Aromarizer cover off once more to
plug in the light.
Insert and connect one end of the flow system to the oxygen concentrator. Connect the other end of the flow
system to the black manifold valve assembly on the rear shelf of the Aromarizer. Make sure at least one black
manifold valve on the Aromarizer is in the on position. Each bottle has it’s own on and off valve. To turn on a
specific bottle, turn the corresponding black manifold valve counterclockwise a few turns. To turn it off, turn the
corresponding black manifold valve clockwise until it doesn’t turn anymore.
_____________________________________________________________________________________________________________
_____________________________________________________________________________________________________________
Check Valves------------------------------------>--
<----------Nose Hose
Connection Tubes
AOCS Connection--------------->
to Black Manifold Valves
(Shown in blue)
Red Cap Assembly--------------------------------->
Side Arm--------------------------------------->
Glass Rod------------------------------------------->
Click the photo to enlarge
|
©1998 - 2009 Airheads Oxygen Bars, Inc.
|